2722-8K400VLS3700-00240V50HzLS3700-16125VLS3700-1824VCCLS3700-1948VCCLS3700-50110VCCLS3700-51220VCCLS3700-54230VLS3700-55240VLS3700-5742VLS3700-5824VLS3700-5948VLS3722-00110VLS3722-16400VLS3722-1724VLS3722-1848VLS3722-1960VCCLS3722-50110VCCLS3722-51220VCCLS3722-55230VLS3722-57240VLS3722-5824VLS3722-5948VLS3722-8K110VLS4700-50400VLS4700-55125VLS4700-57230VLS4700-5824VLS4700-5948VLS4722-50110VLS4722-51400VLS4722-53230VLS4722-55240VLS4722-57440VLS4722-5824VLS4722-5948VLS4722-84110VLS4722-8K400VLS5700-5042VLS5700-55125VLS5700-57230VLS5700-5824VLS5700-5948VLS5722-50110VLS5722-51400VLS5722-55230VLS5722-57240VLS5722-5824VLS5722-5948VLS5722-63110VLS5722-8K400VLS7711-58380VLS7722-53125VLS7722-55110VLS7722-57440VLS7722-5824VLS7722-5948VLS8722-50110VLS8722-55400VLS8722-58230VLS8722-5924VLS7722-50110VLS10722-50400VLS10722-55230VLS10722-57230VLS10722-5824VLS10722-5948VLS10722-5C110VLS10722-69400VLS10722-80125VLS10722-84220/60LS10722-86415VLS10722-8942VLS14722-00115/60LS14722-50230/60LS14722-55230。扬州交流高压卧式真空接触器,无锡海邦机械供应。新型 交流高压卧式真空接触器厂家拿货价格
当前位置:电工之家>电工知识>接触器>正文交流接触器主触点在不同电压下的额定电流怎么看时间:2018-12-2812:34来源:电工之家接触器的型号很多,国产系列我常用到的有CJ10系列、CJ20系列、CJX1和CJX2系列!国内的接触器型号是比较规范的,比如CJX1-22/22接触器,CJX1是表示接触器的规格系列,前面的22就是380V时主触点的额定电流,后面的22就是表示两个常开点,两个常闭点!要看接触器的具体参数,可以看接触器侧面的标签!圈内的部分就是主触点在不同电压下的额定电流!再如CJX2-2501就表示CJX2系列接触器,380V额定电流25A,01**的是辅助触点的个数,前面的是常开触点,后面的为常闭触点,这个就是**一对常闭触点,常开触点没有!像施耐德还有一些国外品牌的接触器的命名方式就不太一样了,而且也没有统一的标准,只能查看说明书或者侧面标签来确定参数!这是施耐德的LC1D25A的接触器,从型号还是可以看出额定电流是25A的!一些国外的品牌就不是很容易看出来了,***没找到那些接触器,下次找到会发上来补上!这些东西都是凭经验来的,用的多了自然就会对这些有一定的了解,只凭这里的只言片语很难说明白!注意多看多用心就会有收获了!黑龙江交流高压卧式真空接触器***报价交流高压卧式真空接触器厂商,无锡海邦机械供应。
对于启动时间长的负载,半小时峰值电流不能超过约定发热电流!(3)按短时的动、热稳定校验!线路的三相短路电流不应超过接触器允许的动、热稳定电流,当使用接触器断开短路电流时,还应校验接触器的分断能力!(4)接触器吸引线圈的额定电压、电流及辅助触头的数量、电流容量应满足控制回路接线要求!要考虑接在接触器控制回路的线路长度,一般推荐的操作电压值,接触器要能够在85~110%的额定电压值下工作!如果线路过长,由于电压降太大,接触器线圈对合闸指令有可能不起反映;由于线路电容太大,可能对跳闸指令不起作用!(5)根据操作次数校验接触器所允许的操作频率!如果操作频率超过规定值,额定电流应该加大一倍!(6)短路保护元件参数应该和接触器参数配合选用!选用时可参见样本手册,样本手册一般给出的是接触器和熔断器的配合表!(7)接触器和其它元器件的安装距离要符合相关国标、规范,要考虑维修和走线距离!注意:接触器和空气断路器的配合要根据空气断路器的过载系数和短路保护电流系数来决定!接触器的约定发热电流应小于空气断路器的过载电流,接触器的接通、断开电流应小于断路器的短路保护电流,这样断路器才能保护接触器!
7FReiheLS57CS77RReiheLS57CS87RReiheLS77LS4K01-55ReiheLS77LS4K01-00ReiheLS87LS4K01-5724VLS4K01-1624VCCLS4K01-5648VLS4K01-5048VCCLS4K01-59110VLS4K10-1B230VLS4K10-55400VLS4K10-0012VCCLS4K10-5724VLS4K10-1624VCCLS4K10-5648VLS4K10-8748VCCLS4K10-50110VLS4K10-59110V/60LS5K00-56230VLS5K01-55400VLS5K01-00110VLS5K01-1624VLS5K01-5624VCCLS5K01-1848VCCLS5K01-14110VLS5K01-19110VCCLS5K01-50125VCCLS5K01-59220VCCLS5K10-1B230VLS5K10-55400VLS5K10-0012VCCLS5K10-8E24VLS5K10-1624VCCLS5K10-5648VLS5K10-8848VCCLS5K10-18110VLS5K10-50110V50HzLS5K10-59110VCCLS5K2200-55230VLS5K2200-00400VLS5K2200-5724VLS5K2200-1624VCCLS5K2200-56048VLS5K2200-1848VCCLS5K2200-50110VLS5K400-55110CCLS5K400-00230VLS5K400-1624VLS5K400-5624VCCLS5K400-1848VCCLS5K400-14110VLS5K400-19110VCCLS5K400-50125VCCLS5K400-20220VCCLS5K400-59230VLS7K00-55250VCCLS7K00-56400VLS7K00-5024VLS7K00-00110VLS7K01-1B230VLS7K01-55230/50LS7K01-0012VCCLS7K01-5424VLS7K01-5724VCCLS7K01-1642VLS7K01-1748VLS7K01-5648VCCLS7K01-1860VCCLS7K01-50110VLS7K01-59110VCCLS7K10-5。新疆交流高压卧式真空接触器,无锡海邦机械供应。
静导电排改为两端上弯出线图55U一、二次接线端都改到基本型的反面图56VW控制电源盒与接触器分离,在外部安装。接触器上有连接端子图8XYZ注:上表中各改型序号可以合理组合派生出多种不同型号的接触器。b.产品规格分别为额定电压为、12kV,额定电流为160A、250A、400A、630A4.结构及工作原理本系列接触器由绝缘框架、金属底座、传动拐臂、电磁系统、辅助开关和真空灭弧室等部件组成(见图1)。当电磁线圈通过控制电压时,衔铁带动拐臂转动,使真空灭弧室内主触头接通,电磁线圈断电后,由于分闸弹簧作用,使主触头分断。真空灭弧室由上封盖、下封盖、金属波纹管和陶瓷管等组成,该真空灭弧室,外壳采用95瓷绝缘材料制成波纹式的瓷管,它具有爬电距离大、机械强度高、耐热和耐冲击的特点。真空灭弧室内封装一对动静触头,触头材料采用耐磨且低截流值的Cu-W-Wc,这样在满足开断性能的条件下,减小开断过程中由于截流引起的过电压,提高了真空灭弧室的使用电寿命。当金属波纹管轴向运动时带动动触头做分合闸动作。电磁系统考虑实际吸力特性与反力特性良好配合,以及发挥接触器运行时噪音低、节电的优点,采用直流双线圈由起动和维持两绕组组成,通过辅助开关切换。吉林交流高压卧式真空接触器,无锡海邦机械供应。湖北固态交流高压卧式真空接触器
交流高压卧式真空接触器供应,无锡海邦机械供应。新型 交流高压卧式真空接触器厂家拿货价格
但是由于互锁的原因,只能处于模拟工作状态,即其系统的界面上可以模拟驱动***伺服驱动电机或第二伺服驱动电机转动,但是两个机床数控系统共用的主轴驱动器驱动的传动机构与hnc-210b数控系统plc控制器或fanuc模拟主轴模块的传动机构机械断开连接。如图4所示,机床供电系统的两相供电电源输入端220e、220c经过开关电源vc2提供直流+24v电压,如图2开关电源vc2的正极24c经保护空开qf8电性连接两档选择开关sa1的静片,两档选择开关sa1的输出端kah和kaf与开关电源vc2的负极101之间包括并联的接触器互锁电路:hnc-210b数控系统启动电路包括依次串联的第二数控系统启动按钮sb1h、钥匙按钮sb2h、接触器kaf1辅助动断触点、kah1继电器线圈,及与第二数控系统启动按钮sb1h并联的接触器kah1辅助动合触点;fanuc数控系统启动电路包括依次串联的***数控系统启动按钮sb1f、钥匙按钮sb2f、接触器kah1辅助动断触点、kaf1继电器线圈,及与***数控系统启动按钮sb1f并联的接触器kaf1辅助动合触点。kah1继电器线圈还与kah2继电器线圈并联,kaf1继电器线圈还与kaf2继电器线圈并联。当选择hnc-210b数控系统时,两档选择开关sa1向输出端kah拨动,在钥匙按钮sb2h中插入第二数控系统的启动钥匙。新型 交流高压卧式真空接触器厂家拿货价格